HP HPE0-S50 Exam Practice Questions (P. 4)
- Full Access (53 questions)
- Six months of Premium Access
- Access to one million comments
- Seamless ChatGPT Integration
- Ability to download PDF files
- Anki Flashcard files for revision
- No Captcha & No AdSense
- Advanced Exam Configuration
Question #16
Refer to the exhibit.

How should a Synergy integrator pair interconnect bays to set up redundant fabrics in an HPE Synergy 12000 Frame?

How should a Synergy integrator pair interconnect bays to set up redundant fabrics in an HPE Synergy 12000 Frame?
- AInterconnect bays 1 and 2; bays 3 and 4; bays 5 and 6.
- BInterconnect bays 1 and 4; bays 2 and 5; bays 3 and 6.
- CInterconnect bays 1 and 6; bays 2 and 5; bays 3 and 4.
- DInterconnect bays 1 and 3; bays 2 and 4; bays 5 and 6.
Correct Answer:
B
References:
https://h20195.www2.hpe.com/v2/GetPDF.aspx/c04815113.pdf
(13)
B
References:
https://h20195.www2.hpe.com/v2/GetPDF.aspx/c04815113.pdf
(13)
send
light_mode
delete
Question #17
While troubleshooting a hardware issue, a Synergy integrator needs to provide HPE Support with a new support dump.
What must the integrator be aware of when generating a support dump?
What must the integrator be aware of when generating a support dump?
- AWhen creating a new support dump, the previous support dump is deleted.
- BOnly two support dumps can exist on an appliance at any one time.
- CRoot level privileges are required to create a support dump.
- DManagement tasks are suspended during support dump creation.
Correct Answer:
B
B
send
light_mode
delete
Question #18
A customer has a single frame with seven compute modules in bays 1-7. The customer also has an HPE Synergy 12Gb SAS Connection Module in slot 1. The customer recently made a change to require high availability for its storage.
What should the Synergy integrator do to meet the customer's requirement for high availability?
What should the Synergy integrator do to meet the customer's requirement for high availability?
- AInstall an additional HPE D3940 storage module to support bays 7-12.
- BMove the compute module from bay 7 to bay 12.
- CAdd another HPE Synergy 12Gb SAS Connection Module to bay 4.
- DMove the mezzanine Card to slot 2 on each compute module.
Correct Answer:
C
C
send
light_mode
delete
Question #19
A customer needs a consolidated infrastructure view for HPE Synergy and HPE BladeSystem c7000 enclosures.
Which approach should the Synergy integrator take to meet the customer's needs?
Which approach should the Synergy integrator take to meet the customer's needs?
- AEnable federation in the HPE OneView appliance and add remote HPE OneView instances.
- BAdd remote enclosures to monitor the BladeSystem c7000 enclosures.
- CDeploy HPE OneView Global Dashboard.
- DExtend the Synergy out-of-band management ring to the c7000 Onboard Administrator ports.
Correct Answer:
C
C
send
light_mode
delete
Question #20
Which utility compares currently running firmware with the upgrade firmware for the HPE Synergy 40Gb F8 Switch Module, which allows minimal downtime during the upgrade?
send
light_mode
delete
All Pages