Question #11
An administrator needs to change the RAID type from RAID 10 to either RAID 50 or RAID 6.
What must the administrator select before Modify RAID Configuration within the Activities pane?
What must the administrator select before Modify RAID Configuration within the Activities pane?
- ATools within the Tool pane
- BStorage Pools within Group pane
- CMember within the Group pane
- DGroup Configuration within the Group pane
Correct Answer:
B
Pools allow you to organize storage by RAID type.
B
Pools allow you to organize storage by RAID type.
send
light_mode
delete
Question #12
According to Dell recommendations, when should a firmware update be performed on a PS Series group?
- AFirmware upgrades should be performed on the weekends.
- BFirmware updates should be done during low I/O periods.
- CFirmware updates must always be done during a maintenance window.
- DFirmware upgrades may be performed during any I/O period.
Correct Answer:
B
Dell recommends that you perform firmware updates during periods of low activity. If possible, perform the update after a backup.
References: Updating Firmware for Dell EqualLogic PS Series Storage Arrays and FS Series Appliances, page 9 http://en.community.dell.com/dell-groups/dtcmedia/m/mediagallery/20381147/download
B
Dell recommends that you perform firmware updates during periods of low activity. If possible, perform the update after a backup.
References: Updating Firmware for Dell EqualLogic PS Series Storage Arrays and FS Series Appliances, page 9 http://en.community.dell.com/dell-groups/dtcmedia/m/mediagallery/20381147/download
send
light_mode
delete
Question #13
A VMware administrator requests the creation of a 100 GB volume to use as a datastore on an ESX environment. The SAN administrator completes the request.
For a few days, the VMware administrator is able to access and use the datastore. The VMware administrator then reports that the VM located on the datastore is greyed out and labelled as inaccessible.
What are three possible reasons for this problem? (Choose three.)
For a few days, the VMware administrator is able to access and use the datastore. The VMware administrator then reports that the VM located on the datastore is greyed out and labelled as inaccessible.
What are three possible reasons for this problem? (Choose three.)
- AThe SAN administrator has NOT set the datastore access policy.
- BThe SAN administrator recently upgraded firmware revision on the array.
- CThe SAN administrator has changed and set an incorrect access policy.
- DThe SAN administrator set the datastore volume as "Read Only".
- EThe ESXi host is unable to ping the Storage group.
Correct Answer:
BCE
Incorrect Answers:
A: The datastore access policy worked fine for a few days.
BCE
Incorrect Answers:
A: The datastore access policy worked fine for a few days.
send
light_mode
delete
Question #14
A customer has a multi-member, multi-pool group in production. The load on the pools is NOT balanced.
Which two methods should a SAN administrator use to balance the load between the pools? (Choose two.)
B. Within the Group Manager Volumes tab, right-click a volume, select "Move Volume".
D. Within the Group Manager Group tab, right-click a volume, select "Move Volume".
Which two methods should a SAN administrator use to balance the load between the pools? (Choose two.)
B. Within the Group Manager Volumes tab, right-click a volume, select "Move Volume".
D. Within the Group Manager Group tab, right-click a volume, select "Move Volume".
Correct Answer:
AB
To move a volume to a new pool:
1.Click Volumes.
2.Expand Volumes and select the volume name.
3.Click Move volume to open the Move volume dialog.
4.If you are changing the pool assignment for a synchronous replication volume, you must specify the SyncActive or SyncAlternate volume.
5.Select the destination pool for the volume.
6.Click OK.
The volume status is shown as moving until the pool move operation completes.
References:
http://psonlinehelp.equallogic.com/en/V6.0/groupmanager.htm
(Moving a Volume to a Pool)
AB
To move a volume to a new pool:
1.Click Volumes.
2.Expand Volumes and select the volume name.
3.Click Move volume to open the Move volume dialog.
4.If you are changing the pool assignment for a synchronous replication volume, you must specify the SyncActive or SyncAlternate volume.
5.Select the destination pool for the volume.
6.Click OK.
The volume status is shown as moving until the pool move operation completes.
References:
http://psonlinehelp.equallogic.com/en/V6.0/groupmanager.htm
(Moving a Volume to a Pool)
send
light_mode
delete
Question #15
A customer is moving to a new datacenter and needs to put the existing two members into a new subnet. Each array has two iSCSI ports. The group does NOT use a dedicated management port.
What is the correct sequence of steps to change all physical and group IPs on the members to the new subnet?
What is the correct sequence of steps to change all physical and group IPs on the members to the new subnet?
- A- Change 1st port array physical ports first - Change Group IP second - Change 2nd port array physical ports last
- B- Change Group IP first - Change 2nd port array physical ports second - Change 1st port array physical ports last
- C- Change 1st port array physical ports first - Change 2nd port array physical ports second - Change Group IP last
- D- Change 2nd port array physical ports first - Change Group IP second
Correct Answer:
C
Note:
* Changing the group IP address disconnects any iSCSI connections to the group and any administrators logged in to the group through the group IP address.
* If you change the IP address of a group for which you are running the GUI locally, or configure a management network for the group, you must uninstall the standalone GUI application and then install it again.
References:
http://psonlinehelp.equallogic.com/en/V6.0/groupmanager.htm
(About Group Network Configuration)
C
Note:
* Changing the group IP address disconnects any iSCSI connections to the group and any administrators logged in to the group through the group IP address.
* If you change the IP address of a group for which you are running the GUI locally, or configure a management network for the group, you must uninstall the standalone GUI application and then install it again.
References:
http://psonlinehelp.equallogic.com/en/V6.0/groupmanager.htm
(About Group Network Configuration)