Question #31
Two sets of OceanStor unified storage with synchronous remote replication are effective in the following ways to improve host write performance on the primary storage:
(Multiple choice.)
(Multiple choice.)
- ARPO does not require 0 for the scenario, it is recommended to use asynchronous remote replication.
- BThe main storage using smart cache acceleration, speed up the main storage IO processing speed.
- CAccording to the service pressure of the LUNs stored on the primary side, assign the home controllers of each LUN to the A and B controllers.
- DIf you are using an asynchronous remote replication scheme, you need to design a startup synchronization time based on the RPO metrics and consider the
Correct Answer:
ACD
ACD
send
light_mode
delete
Question #32
When a customer uses simpana software, CS can not start normally due to some reason and needs to recover the CS. Which of the following situations will cause the restoration to fail?
- AThe backup server and the media server can not communicate properly.
- BThe link between the backup media and the media server is down.
- CBackup server SQL database failure.
- DDDB is abnormal.
Correct Answer:
C
C
send
light_mode
delete
Question #33
Customers use Redhat Linux enterprise 6 LVM to manage user data disks in the cluster. What is the possible reason, when using pvmove data migration can not enforce OK?
- APvmove command does not support Linux cluster.
- BRedhat Linux enterprise 6 version of lvm does not support the pvmove command.
- CYou need to install the cmirror package and run it on the cluster server.
- DNeed to lvm version down to 1.0 before using pvmove migration data.
Correct Answer:
C
C
send
light_mode
delete
Question #34
A N8500 (V200R001) clustered NAS system with a set of storage units at the back end. Three RAID Groups, respectively named RG1, RG2, RG3 have been created on the storage unit. There are two LUNs under each RAID group, the capacity of each LUN is 12G.
The names are RG1-LUN1, RG1-LUN2, RG2-LUN1, RG2-LUN2, RG3-LUN1, RG3-LUN2, and all LUNs are added to one in storage pool. The purpose is to create a file system based on these LUNs. What of the following will certainly create a failure?
The names are RG1-LUN1, RG1-LUN2, RG2-LUN1, RG2-LUN2, RG3-LUN1, RG3-LUN2, and all LUNs are added to one in storage pool. The purpose is to create a file system based on these LUNs. What of the following will certainly create a failure?
- Afs create striped fs01 10g 3 RG1-LUN1, RG2-LUN1, RG3-LUN1 stripeunit = 2048 blksize = 8192
- Bfs create mirrored fs02 10g 2 RG1-LUN2, RG2-LUN2 stripeunit = 2048 blksize = 8192
- Cfs create mirrored-stripe fs03 10g 2 2 RG1-LUn1, RG2-LUN1 protection = disk stripeunit = 2048 blksize = 8192
- Dfs create striped-miiro fs04 20g 2 3 RG1-LUn1, RG1-LUN2, RG2-LUN1, RG2-LUN2, RG3-LUN1, RG3-LUN2 protection = disk stripeunit = 512 blksize = 1024
Correct Answer:
C
C
send
light_mode
delete
Question #35
Redhat Linux Enterprise 6 cp command is used to complete the operating system data migration. What steps are needed to verify confirmation transfer into
Power? (Multiple choice.)
Power? (Multiple choice.)
- ACheck if the size of the migrated file is the same as the original data.
- BCheck if the number of documents corresponds to the original data
- CCheck if each file with read and write permissions corresponds to the original data
- DWhether the time for reviewing the case file corresponds to the original data.
Correct Answer:
ABC
ABC
send
light_mode
delete
Question #36
HPUX system has two user volume groups: VG01 and VG02. Execute the following command vgexport-v-s-p -m /tmp/vg01.map / dev / vg01 and vgexport-v -s - m /tmp/vg01.map / dev / vg02. Can vglist view the volume group then?
send
light_mode
delete
Question #37
A banking business running background storage system requirements are as follows:
(1) Business Impact. The business impact generated by the operating system is about 100KB.
(2) The service operation system is the whole GE network. The server and operating system are GE network. Follow-up to consider the business needs to upgrade to 10GE.
(3) Only requires 72TB of total space, the latter expansion priority to expand the disk
(4) Only 20U of rack space is reserved for the current storage devices. The configuration of three nodes and switches is prioritized to meet the requirements of the machine room. Cabinet planning based on the above requirements.
What are the more appropriate networking solutions?
(1) Business Impact. The business impact generated by the operating system is about 100KB.
(2) The service operation system is the whole GE network. The server and operating system are GE network. Follow-up to consider the business needs to upgrade to 10GE.
(3) Only requires 72TB of total space, the latter expansion priority to expand the disk
(4) Only 20U of rack space is reserved for the current storage devices. The configuration of three nodes and switches is prioritized to meet the requirements of the machine room. Cabinet planning based on the above requirements.
What are the more appropriate networking solutions?
- AProgram One: 1 * OceanStor 9000 C Node 36 * 2TB SATA configuration 2 * Front-end GE + 2 * Rear-end 10GE
- BScenario 2: 3 * Oceanstor 9000 C Node 36 * 2TB SATA hard drive; 2 * Front-end GE + back-end 2 * 10GE
- Cprogram three: 3 * OceanStor 9000 P Node 36 * 2TB SAS configuration 2 * Front-end GE + 2 * Rear-end 10GE
- DProgram Four: 3 * OceanStor 9000 M Node 36 * 2TB SAS configuration
Correct Answer:
C
C
send
light_mode
delete
Question #38
Which of the following best practice description of Oralce database is correct? (Multiple choice.)
- AOLAP business query output is usually a statistical value (using group by with order by), so you can set a larger SGA-target value (relative to OLTP).
- BIt is recommended to use UDEV UUID and drive letter binding, in Linux environment configuration Oracle database, to avoid subsequent maintenance letter changes caused by the database which can not start.
- CIf the database OLTP business log write is very frequent, it is recommended that the appropriate online log file up, but it is recommended not to exceed 128MB.
- DIn Windows2008 or windows2012 operating system environment, in order to improve I / O processing efficiency, MBR partition is created, and diskpart
Correct Answer:
BCD
BCD
send
light_mode
delete
Question #39
Which of the following is a description of the UltraPath multipath setting? (Multiplexed.)
- AThe mode of operation of the array can be in-controller load balancing or inter-controller load balancing.
- BLoad Balancing Mode Including wheel training algorithm, the maximum queue depth algorithm, the maximum workload algorithm.
- CAfter the connection is interrupted between the LUN home controller and the host, the host accesses the LUN through the peer controller. In this case, the over-trail software defaults the switched home controller of the LUN to the remote controller.
- DWhen multipath detects a preferred controller failure recovery, the I / O is resumed immediately at the preferred controller by default.
Correct Answer:
AC
AC
send
light_mode
delete
Question #40
The disaster recovery plan of Huawei means that when the production site fails, the production business is automatically switched to run the disaster recovery site.