Question #6
An architect needs to help a customer design a management and monitoring solution for an Aruba network in an airport. The solution consists of an Aruba Mobility
Master (MM), Aruba 7210 MCs, Aruba AP-335s, and Aruba 5496R switches. The architect plans to recommend Aruba AirWare.
The airport has a high-client device turnover and many highly mobile devices. Which changes should the architect make to the recommended solution based on this characteristic?
Master (MM), Aruba 7210 MCs, Aruba AP-335s, and Aruba 5496R switches. The architect plans to recommend Aruba AirWare.
The airport has a high-client device turnover and many highly mobile devices. Which changes should the architect make to the recommended solution based on this characteristic?
- ARecommend additional hardware resources beyond those recommended for the typical tested AirWare platform.Most Voted
- BRecommend extra AirWare device licenses to support the changing number of client devices.
- CRecommend Aruba Central with a Clarity subscription as a more flexible cloud-based solution.
- DRecommend Aruba Central with guest access licensing to increase guest visibility.
Correct Answer:
B
B
send
light_mode
delete
Question #7
An architect proposes four 7210 Mobility Controllers (MCs) to support about 1,500 client APs. The customer environment will have a maximum of about 20,000 wireless clients. The customer wants hardware MMs with an active and standby deployment. What is the minimum solution that meets the customer requirements?
- Atwo MM-HW-10K appliances
- Btwo MM-HW-5K appliances
- Cfour MM HW-5K appliances
- Dfour MM HW-10K appliances
Correct Answer:
B
B
send
light_mode
delete
Question #8
A financial institution has an Aruba wireless system. Each floor is 19 meters by 23 meters (200 feet by 250 feet) and has 20 APs. The organization now requires dedicated Air Monitors (AMs). About how many AMs should the architect recommend per floor?
- Aabout 1 or 2 per floor
- Babout 3 to 5 per floorMost Voted
- Cabout 10 to 12 per floor
- Dabout 16 to 20 per floor
Correct Answer:
A
A
send
light_mode
delete
Question #9
A customer needs a solution to terminate VPN tunnels for Aruba RAPs. The customer has a single site and a single public IP address for this purpose. Network address translation (NAT) will forward the IPsec traffic to the correct device to terminate the VPN tunnel. The customer also requires N+1 redundancy for the solution. Which solution meets the customer requirements?
- Atwo Aruba MCs on the same subnet that use VRRP without clusteringMost Voted
- Btwo Aruba MCs deployed as a Layer 3 cluster
- Ctwo Aruba MCs on different subnets that use VRRP without clustering
- Dtwo Aruba MCs deployed as a Layer 2 cluster
Correct Answer:
B
B
send
light_mode
delete
Question #10
An architect needs to plan the RF coverage. Which application has the greatest potential impact on RF design?