Question #6
Refer to the exhibit.

An integrator needs to add an FCoE connection to the server profile, but the FCoE connection type is not available.
What is the likely cause of this issue?

An integrator needs to add an FCoE connection to the server profile, but the FCoE connection type is not available.
What is the likely cause of this issue?
- AFCoE capable interconnect modules are not installed in the Synergy frame
- BDefined FCoE network is not associated with a SAN or does not have VLAN Id defined
- CA FCoE connection is not available, as there is no LIG configured for FCoE connectivity
- DThe FCoE connection has not been added as a Fibre Channel connection within a server profile
Correct Answer:
D
D
send
light_mode
delete
Question #7
An integrator is installing three Synergy frames in different locations for a customer. As part of the installation, the customer requests a single monitoring dashboard that shows the current hardware status, warranty status, and open support cases of all three frames.
Which configuration steps must the integrator perform to provide the customer with this functionality?
Which configuration steps must the integrator perform to provide the customer with this functionality?
- AEnable Remote Support and Insight Online Integration in the Composer UI
- BInstall Insight Remote Support Advanced, and integrate it with HPE Global Dashboard
- CConfigure OneView with iLO Amplifier pack
- DActivate iLO Federation on all installed compute nodes
Correct Answer:
C
C
send
light_mode
delete
Question #8
What are valid uses for an IPv4 address pool when configuring an HPE Synergy solution? (Choose two.)
- Aassignment of IP addresses for NICs in an operating system
- Bassignment of IP addresses for Composer appliances
- Cassignment of IP addresses for PXE booting to a deployment server
- Dassignment of IP addresses for interconnect modules
- Eassignment of IP addresses for iLOs
Correct Answer:
DE
Reference:
https://techlibrary.hpe.com/docs/synergy/shared/setup_overview/index.html
DE
Reference:
https://techlibrary.hpe.com/docs/synergy/shared/setup_overview/index.html
send
light_mode
delete
Question #9
HOTSPOT -
A customer has the following HPE Synergy solution:
✑ three Synergy frames
✑ two HPE Virtual Connect SE 32Gb Fibre Channel (FC) modules in each time
✑ two HPE Virtual Connect SE 40GB F8 modules
✑ four HPE Synergy 10Gb Interconnect Link Modules
Click the menu option the integrator should use to add more uplinks ports from HPE Virtual Connect SE 32 Gb FC modules to SAN uplink set.
Hot Area:

A customer has the following HPE Synergy solution:
✑ three Synergy frames
✑ two HPE Virtual Connect SE 32Gb Fibre Channel (FC) modules in each time
✑ two HPE Virtual Connect SE 40GB F8 modules
✑ four HPE Synergy 10Gb Interconnect Link Modules
Click the menu option the integrator should use to add more uplinks ports from HPE Virtual Connect SE 32 Gb FC modules to SAN uplink set.
Hot Area:

send
light_mode
delete
Question #10
Which policy can an integrator apply when creating a datastore using HPE OneView for vCenter Server?
- AData at Rest encryption policy
- BRound Robin load balancing policy
- CRecovery Manager Central policy
- Dvirtual machine Restart policy
Correct Answer:
C
C
send
light_mode
delete