Dell DSDSC-200 Exam Practice Questions (P. 5)
- Full Access (116 questions)
- Six months of Premium Access
- Access to one million comments
- Seamless ChatGPT Integration
- Ability to download PDF files
- Anki Flashcard files for revision
- No Captcha & No AdSense
- Advanced Exam Configuration
Question #21
What are two 1 Gb iSCSI best practices to set up and-to-end connectivity (servers, switch, and storage)? (Choose two.)
- AFlow Control
- BJumbo Frame
- CSpanning Tree
- DUnicast Storm Control
Correct Answer:
BC
Reference -
http://en.community.dell.com/techcenter/extras/m/white_papers/20437971/download
BC
Reference -
http://en.community.dell.com/techcenter/extras/m/white_papers/20437971/download
send
light_mode
delete
Question #22
A zone must include at least one target and at least one initiator.
How many targets and initiators should each zone include according to recommended best practice?
How many targets and initiators should each zone include according to recommended best practice?
- Asingle initiator; multiple target
- Bsingle initiator; single target
- Cmultiple initiator; multiple target
- Dmultiple initiator; single target
Correct Answer:
A
For server zones, it is a best practice to use single-initiator, multiple-target zones. For example, for each Fibre Channel port on the server, create a server zone that includes the HBA WWN and all the virtual WWNs on the SC Series array controllers.
A
For server zones, it is a best practice to use single-initiator, multiple-target zones. For example, for each Fibre Channel port on the server, create a server zone that includes the HBA WWN and all the virtual WWNs on the SC Series array controllers.
send
light_mode
delete
Question #23
An engineer is configuring fault domains and front-end IO ports on a dual controller storage array. Any volumes that are later created and mapped to a server must be active/optimized on one controller and standby on the other controller.
Which port mode should the engineer use to meet this requirement?
Which port mode should the engineer use to meet this requirement?
- APhysical Port Mode
- BVirtual Port Mode
- CLegacy Port Mode
- DALUA Port Mode
Correct Answer:
C
C
send
light_mode
delete
Question #24
A customer has a newly installed storage array. The customer needs to proactively monitor and report storage utilization on a regular basis.
Which customizable, proactive tool should be configured to perform this task?
Which customizable, proactive tool should be configured to perform this task?
- AEnterprise Manager Threshold Alerting
- BDell SupportAssist
- CStorage Center Event Monitoring
- DEnterprise Manager Automated Reporting
Correct Answer:
A
A
send
light_mode
delete
Question #25
A customer has multiple Storage Centers at their main site and a DR system at a remote site. A particularly important volume requires High Availability protection.
An outage on one system at the main location must NOT cause data to be inaccessible. Disaster Recovery protection is also required to protect data even if the entire main site goes down.
Which technology best meets these requirements?
An outage on one system at the main location must NOT cause data to be inaccessible. Disaster Recovery protection is also required to protect data even if the entire main site goes down.
Which technology best meets these requirements?
- AAsynchronous Replication
- BLive Volume Managed Replication
- CFluid Data Architecture
- DSynchronous Replication
Correct Answer:
B
B
send
light_mode
delete
All Pages