Question #16
A storage array is configured with four front-end ports on each controller (in a dual-controller configuration) for server connectivity. The storage array runs in
Legacy Port mode. An engineer needs to provide multi-pathed (2 fabrics) connectivity from the storage array to the server.
What is the minimum number of fault domains required?
Legacy Port mode. An engineer needs to provide multi-pathed (2 fabrics) connectivity from the storage array to the server.
What is the minimum number of fault domains required?
send
light_mode
delete
Question #17
There are several servers connected to the Storage Center through Fibre Channel (FC) fabrics using WWN zoning. The engineer has recently replaced a servers
FC HB. This server can no longer connect to the Storage Center.
What is causing the problem?
FC HB. This server can no longer connect to the Storage Center.
What is causing the problem?
- AThe Storage Center’s Fault Domains must be updated with the new HBA WWN
- BThe server’s zone must be updated with the new switch port to which the HBA is connected
- CThe Storage Center Fault Domains must be converted to Virtual Port mode
- DThe server’s zone must be updated with the new HBA’s WWN.
Correct Answer:
A
A
send
light_mode
delete
Question #18
An engineer has several servers connected to the Storage Center through two FC fabrics. The Storage Center runs in Virtual Ports mode. The engineer needs to create zones based on World Wide Names (WWN).
Which WWNs from the Storage Center need to be included in the zone with the server WWN?
Which WWNs from the Storage Center need to be included in the zone with the server WWN?
- Aonly the Primary WWNs
- Bonly the Virtual WWNs
- Cboth the Primary and Reserve WWNs
- Dboth the Virtual and Physical WWNs
Correct Answer:
B
B
send
light_mode
delete
Question #19
A deployment engineer is installing a dual-controller Storage Center with four FC ports in each controller. This system need to use Legacy Port mode because the
AIX version used requires it.
Which two configurations are required to set up the fault domains? (Choose two.)
AIX version used requires it.
Which two configurations are required to set up the fault domains? (Choose two.)
- AThere are only two fault domains used, one for primary ports and one for reserved ports.
- BThere is a separate fault domain for each set of primary and reserved ports.
- CThere are only two fault domains used, one for the ports in each fabric.
- DThe primary and reserved ports in the fault domain need to reside on different controllers.
Correct Answer:
CD
CD
send
light_mode
delete
Question #20
An engineer needs to install an SC8000 with four FC ports in each controller and two FC switches set up in a dual fabric. Each controller also has two 10 Gb iSCSI ports. All iSCSI ports are connected to an ethernet switch. The system uses virtual ports.
How many fault domains are required?
How many fault domains are required?
send
light_mode
delete