Question #16
An engineer needs to update BIOS in the following environment:
- Over 100 servers are spread over 10 chassis
- All servers are in the same data center
- The only maintenance window is late Sunday evening when OS patches are applied and servers are rebooted
- Less than 10 minutes of additional downtime per server is allowed
What is the most effective update strategy?
- Over 100 servers are spread over 10 chassis
- All servers are in the same data center
- The only maintenance window is late Sunday evening when OS patches are applied and servers are rebooted
- Less than 10 minutes of additional downtime per server is allowed
What is the most effective update strategy?
- ASelect On Next Reboot when applying the BIOS update via CMC before OS patches are performed.
- BUse Dell Repository Manager to create an ISO with the update that can be booted as part of the OS patch reboot process.
- CConfigure each iDRAC to update from a network share that has a catalog and associated update package to be applied.
- DRun the Dell Update Package (DUP) on each server with the defer reboot option before the OS patch and associated reboot is done.
Correct Answer:
A
A
send
light_mode
delete
Question #17
An engineer is responsible for data center bare metal deployment. The engineer deploys hundreds of servers each week and must repeatedly deploy a standard hardware (HW) configuration and put the OS on the bare metal servers.
How should the engineer automate some of these tasks?
How should the engineer automate some of these tasks?
- AUse OpenManage Essentials to replicate server HW using template and deploy OS
- BUse iDRAC/LC GUI to configure server HW and deploy OS.
- CUse DHCP enabled server configuration profiles and install OS with Lifecycle Controller.
- DUse iDRAC/LC GUI to configure HW and PXE boot to OS installation.
Correct Answer:
A
A
send
light_mode
delete
Question #18
An engineer needs to perform hardware configuration, including RAID, on a new batch of 30 identical server nodes. OpenManage Essentials is installed, and the sever nodes have been discovered via iDRAC.
The engineer needs the most efficient way to replicate the configuration from a single configured system without losing connectivity to the iDRAC.
How should the engineer perform this task?
The engineer needs the most efficient way to replicate the configuration from a single configured system without losing connectivity to the iDRAC.
How should the engineer perform this task?
- AUse racadm to export an SCP with the --replace flag, and import the SCP to the other server nodes.
- BUse racadm to export a Server Configuration Profile (SCP) with the --duplicate flag, then import the SCP to the other server nodes.
- CComplete the Getting Started for Deployment Steps; perform inventory, create a template, and deploy the created template to the server nodes.
- DComplete the Getting Started for Compliance Steps; perform inventory, create a template, and associate the server nodes to the created template.
Correct Answer:
C
C
send
light_mode
delete
Question #19
An engineer configures an Alert Action in the CMC to send an email on Warning and Critical events. Chassis fan and power events are showing up as expected.
Server-specific failures such as memory module failures only indicate that the server has gone into a Critical or Warning state.
What additional configuration needs to be done to be informed via email of the detailed server failure?
Server-specific failures such as memory module failures only indicate that the server has gone into a Critical or Warning state.
What additional configuration needs to be done to be informed via email of the detailed server failure?
- ASelect Server Event under Monitored Alerts Category in CMC.
- BEmail Alert Action for Critical and Warning errors on all iDRACs.
- CSet Include System Event Log (SEL) option in CMC email action.
- DEnable Forward iDRAC events to CMC error log in iDRAC.
Correct Answer:
C
C
send
light_mode
delete
Question #20
An engineer needs to use OME to monitor 4000 servers in the environment.
Which two tasks should the engineer perform to improve OME performance and scalability? (Choose two.)
Which two tasks should the engineer perform to improve OME performance and scalability? (Choose two.)
- AIncrease OME discovery/inventory frequency
- BInstall OME on a physical server
- CInstall OME in a virtual server
- DUse an external SQL instance
Correct Answer:
AD
AD