Question #11
An engineer has been given a new chassis and needs to configure the iDRACs on all servers prior to deploying an OS on them. The iDRACs need to be configured with IP addresses and a new root password.
What is the most efficient method to perform this task?
What is the most efficient method to perform this task?
- AUse CMC QuickDeploy
- BUse iDRAC QuickLaunch
- CUse CMC Server Profiles
- DUse racadm quickdeploy
Correct Answer:
D
D
send
light_mode
delete
Question #12
An engineer has connected a monitor, keyboard, and mouse to a VRTX chassis. The engineer is unable to see or control the first blade.
What must the engineer do to control the first blade with a connected monitor, keyboard, and mouse?
What must the engineer do to control the first blade with a connected monitor, keyboard, and mouse?
- AMap the KVM to the first blade in the Front Panel menu of the CMC.
- BPlug the monitor, keyboard, and mouse into the back of the chassis.
- CEnable the KVM for the chassis and navigate to the first blade.
- DReseat the module that manages access to the monitor, keyboard and mouse.
Correct Answer:
C
Reference:
https://www.google.com/url?
sa=t&rct=j&q=&esrc=s&source=web&cd=2&cad=rja&uact=8&ved=0ahUKEwjMmeHh3rbRAhXTM1AKHVfRAFsQFggsMAE&url=http%3A%2F%
2Fen.community.dell.com%2Fcfs-file%2F__key%2Ftelligent-evolution-components-attachments%2F13-4491-00-00-20-40-24-06%2FUsing-VRTX-
KVM_5F00_DVD.pdf%3Fforcedownload%3Dtrue&usg=AFQjCNGyVD49RHW_lz8ukNqGRSq1MGB-mw&sig2=u-1eUuMSjuAroc3FIjzIhA
C
Reference:
https://www.google.com/url?
sa=t&rct=j&q=&esrc=s&source=web&cd=2&cad=rja&uact=8&ved=0ahUKEwjMmeHh3rbRAhXTM1AKHVfRAFsQFggsMAE&url=http%3A%2F%
2Fen.community.dell.com%2Fcfs-file%2F__key%2Ftelligent-evolution-components-attachments%2F13-4491-00-00-20-40-24-06%2FUsing-VRTX-
KVM_5F00_DVD.pdf%3Fforcedownload%3Dtrue&usg=AFQjCNGyVD49RHW_lz8ukNqGRSq1MGB-mw&sig2=u-1eUuMSjuAroc3FIjzIhA
send
light_mode
delete
Question #13
An engineer needs to replicate BIOS and NIC settings for server nodes installed in the chassis.
Which CMC feature should an engineer use to perform this task?
Which CMC feature should an engineer use to perform this task?
- AAutoConfiguration
- BChassis Profiles
- CQuickDeploy
- DServer Profiles
Correct Answer:
C
Reference:
http://www.dell.com/support/Manuals/us/en/19/dell-cmc-v1.10-fx2/CMC_FX2_FX2s_1.1_UserGuide-v1/Overview?guid=GUID-3A3CA051-1EAF-4F4E-
9B34-47500ACAAAB4&lang=en-us
C
Reference:
http://www.dell.com/support/Manuals/us/en/19/dell-cmc-v1.10-fx2/CMC_FX2_FX2s_1.1_UserGuide-v1/Overview?guid=GUID-3A3CA051-1EAF-4F4E-
9B34-47500ACAAAB4&lang=en-us
send
light_mode
delete
Question #14
A password to the CMC root account on an M1000e server chassis has been misplaced.
What should be done to restore administrative access to the CMC?
What should be done to restore administrative access to the CMC?
- AReset root password using the PASSWORD_RSET jumper
- BIssue password reset from a connected blade’s iDRAC
- CCall Dell tech support and ask to reset CMC password via SupportAssist
- DAccess CMC through serial console and issue the enable secret command
Correct Answer:
A
Reference:
http://www.dell.com/support/manuals/us/en/19/dell-cmc-v5.10-m1000e/CMCM1000e51UG-v1/Resetting-Administrator-Password?guid=GUID-
22C032BF-4A40-4F6D-8CA9-AC5E073ECCE6&lang=en-us
A
Reference:
http://www.dell.com/support/manuals/us/en/19/dell-cmc-v5.10-m1000e/CMCM1000e51UG-v1/Resetting-Administrator-Password?guid=GUID-
22C032BF-4A40-4F6D-8CA9-AC5E073ECCE6&lang=en-us
send
light_mode
delete
Question #15
An engineer responsible for server lifecycle management (e.g. Monitor, Update, Deploy) needs to build a monitoring strategy for a multi-vendor data center. The company has an established third party software as the monitoring and help desk system.
Which option should be used to integrate Dell Server hardware into this monitoring architecture?
Which option should be used to integrate Dell Server hardware into this monitoring architecture?
- AConfigure all Dell iDRACs to send alerts to the third party console. Use OME to do the rest of the lifecycle management.
- BConfigure all Dell iDRACs to send alerts to the third party console. Use iDRAC to perform update and deployment.
- CConfigure all Dell iDRACs to send alerts to OME to filter out wanted alerts and forward to the third party console. Build script to do the rest of the Dell server lifecycle management.
- DConfigure all Dell iDRACs to send alerts to OME to filter out wanted alerts and forward to the third party console. Use OME to do lifecycle management of Dell
Correct Answer:
D
D