Question #1
An engineer is installing two PCIe NICs into an existing VRTX chassis. Node 1 has three PCIe cards assigned to it already. After installation, the engineer is unable to assign the two new NICs to node 1.
What should the engineer do to assign the two PCIe NICs to node 1?
What should the engineer do to assign the two PCIe NICs to node 1?
- AUpdate the CMC firmware
- BPower off the node
- CUpgrade the license
- DReseat the NICs
Correct Answer:
A
A
send
light_mode
delete
Question #2
A VRTX server comes with two server modules. The customer requests to assign three PCIe Adapters per each server module. While performing this configuration, the engineer is unable to assign more than two PCIe Adapters per server module.
What is the cause of this issue?
What is the cause of this issue?
- AThe VRTX chassis came with a CMC Express License.
- BThe CMC configuration needs to be reset to the factory defaults.
- CThe VRTX chassis needs to be updated with the latest firmware.
- DThis is a limitation of VRTX chassis.
Correct Answer:
D
Reference:
http://webcache.googleusercontent.com/search?q=cache:9Kp4lWFwzbsJ:en.community.dell.com/cfs-file/__key/telligent-evolution-components- attachments/13-4491-00-00-20-40-24-15/VRTX-CMC_5F00_Feature-Guide.pdf%3Fforcedownload%3Dtrue+&cd=2&hl=en&ct=clnk&gl=us
D
Reference:
http://webcache.googleusercontent.com/search?q=cache:9Kp4lWFwzbsJ:en.community.dell.com/cfs-file/__key/telligent-evolution-components- attachments/13-4491-00-00-20-40-24-15/VRTX-CMC_5F00_Feature-Guide.pdf%3Fforcedownload%3Dtrue+&cd=2&hl=en&ct=clnk&gl=us
send
light_mode
delete
Question #3
An engineer deploys an FX2 and plugs cables from GB1 and STK/GB2 into the management network switch for path and NIC redundancy. When the chassis is powered up, the management network is adversely affected.
What should the engineer do to fix this issue?
What should the engineer do to fix this issue?
- APlug the CMC Redundancy Dongle into GB1 and STK/GB2
- BConfigure a separate IP address for GB2
- CTurn off STP on the management network switch
- DChange the Management Port 2 setting to Redundant
Correct Answer:
D
D
send
light_mode
delete
Question #4
An engineer is deploying a new server node into an existing chassis for a virtualization cluster. The existing cluster nodes have many modified BIOS settings to meet workload needs.
How should the engineer quickly deploy the new server node with matching BIOS settings?
How should the engineer quickly deploy the new server node with matching BIOS settings?
- AUse System Setup to configure dynamic profile settings based on workload.
- BUse the iDRAC GUI to replicate from an existing server profile.
- CUse the CMC Server Profiles to clone an existing server profile.
- DUse the Lifecycle Controller to mirror a cluster member profile.
Correct Answer:
A
A
send
light_mode
delete
Question #5
An engineer needs to limit the power consumption of a chassis without powering down any server nodes.
Which step should the engineer take to perform this task?
Which step should the engineer take to perform this task?
- AUse the CMC to configure the System Input Power Cap for the chassis
- BUse the iDRAC to configure the Power Cap Policy for each server node
- CUse the CMC to configure the Power Cap Policy for each server node
- DUse the iDRAC to configure the System Input Power Cap for the chassis
Correct Answer:
B
Reference:
http://webcache.googleusercontent.com/search?q=cache:bORqqkUflRwJ:en.community.dell.com/techcenter/extras/m/white_papers/20109038/ download+&cd=2&hl=en&ct=clnk&gl=us
B
Reference:
http://webcache.googleusercontent.com/search?q=cache:bORqqkUflRwJ:en.community.dell.com/techcenter/extras/m/white_papers/20109038/ download+&cd=2&hl=en&ct=clnk&gl=us