Cisco® 300-615 Exam Practice Questions (P. 5)
- Full Access (247 questions)
- Six months of Premium Access
- Access to one million comments
- Seamless ChatGPT Integration
- Ability to download PDF files
- Anki Flashcard files for revision
- No Captcha & No AdSense
- Advanced Exam Configuration
Question #21
An attempt to use a global vNIC redundancy template pair results in a service profile that fails to apply. Which action resolves the issues?
- ACreate the peer names before creating the templates.
- BAssign the secondary template first, and then set the peer name.
- CAssign both templates simultaneously.
- DAssign the primary template first, and then set the peer name.Most Voted
Correct Answer:
D
D
send
light_mode
delete
Question #22
An engineer attempts to register Cisco UCS Manager to Cisco UCS Central, but the registration fails. The engineer can ping Cisco UCS Central from UCS
Manager. Which two actions must the engineer attempt to resolve the problem? (Choose two.)
Manager. Which two actions must the engineer attempt to resolve the problem? (Choose two.)
- ASynchronize the date and time to NTP for Cisco UCS Central and the Cisco UCS domains.
- BApply the UCS Central license to UCS Central.
- CPlace Cisco UCS Manager on the same subnet as Cisco UCS Central.
- DAllow port 443 between Cisco UCS Manager and Cisco UCS Central.
- EAllow port 9443 between Cisco UCS Manager and Cisco UCS Central.
Correct Answer:
AD
AD
send
light_mode
delete
Question #23
A Cisco ACI environment consists of three Cisco APICs, two spine switches, and four leaf switches. The engineer erases and reboots all APICs first, then leaf and spine switches individually, and then completes the Initial Setup dialog on the APIC1 CIMC KVM console. When the engineer logs in to the APIC1 web GUI, the engineer notices that there are no directly connected leaf switches being discovered under Fabric > Inventory > Fabric Membership. What is the cause of the issue?
- AThe leaf nodes were not erased properly, which caused a fabric parameters mismatch with the APIC1.Most Voted
- BRebooting the APICs and the leaf and spine switches after wiping them is not required.
- CThe engineer did not enter the TEP Pool value during the Initial Setup dialog on APIC1.
- DThe same Fabric Name value should be used before and after wiping all devices.
Correct Answer:
C
C
send
light_mode
delete
Question #24
DRAG DROP -
Drag and drop the Cisco UCS SNMP fault types from the left onto the correct issues on the right.
Select and Place:

Drag and drop the Cisco UCS SNMP fault types from the left onto the correct issues on the right.
Select and Place:

send
light_mode
delete
Question #25
An engineer must replace a failed memory on a Cisco UCS B-Series Blade Server. After the replacement was done, the server has a "resolve slot" warning.
Which server maintenance action resolves the issue?
Which server maintenance action resolves the issue?
- APerform diagnostic interrupt on the server.
- BRe-acknowlegement the server.
- CReset the server.
- DDecomission the server.
Correct Answer:
B
B
send
light_mode
delete
All Pages