Question #21
What is an Overlay Transport Virtualization extended VLAN?
- Athe user VLAN that exists in multiple sites
- Bthe VLAN that must contain the overlay interface
- Cthe VLAN used to locate other AEDs
- Dthe VLAN used to access the overlay network by the join interface
Correct Answer:
A
A
send
light_mode
delete
Question #22
Which option must be configured when you implement a vPC?
- Athe CCL link, peer link, and vPC member interfaces
- Bthe peer keepalive link, peer link, and vPC member interfaces
- Cthe VSL link, peer link, and vPC member interfaces
- Dthe VSS link, peer link, and vPC member interfaces
Correct Answer:
B
B
send
light_mode
delete
Question #23
Which protocol is used to exchange MAC address reachability between OTV-enabled switches?
- AEIGRP
- BIS-IS
- CiBGP
- DRIPv2
Correct Answer:
B
Reference:
http://www.cisco.com/c/en/us/solutions/collateral/data-center-virtualization/overlay-transport-virtualization-otv/white_paper_c11-702185.htmld
B
Reference:
http://www.cisco.com/c/en/us/solutions/collateral/data-center-virtualization/overlay-transport-virtualization-otv/white_paper_c11-702185.htmld
send
light_mode
delete
Question #24
Which statement accurately describes the implementation of FSPF on Cisco MDS 9700 Series switches?
- AFSPF is enabled on the Fibre Channel switches but must be enabled manually on a per-VSAN basis.
- BFSPF must be enabled manually on the switch and on each VSAN on the switch.
- CFSPF is enabled, by default, on the Fibre Channel switches for all VSANs.
- DFSPF is enabled on VSANs, but must be enabled manually on a per-FC switch basis.
Correct Answer:
A
Reference:
http://www.cisco.com/en/US/products/ps5989/products_configuration_guide_chapter09186a0080662d28.html#wp1288233
A
Reference:
http://www.cisco.com/en/US/products/ps5989/products_configuration_guide_chapter09186a0080662d28.html#wp1288233
send
light_mode
delete
Question #25
Which command should you run to enforce SNMP message encryption for all SNMPv3 communications?
- Asnmp-server globalEnforceAuth
- Bsnmp-server user Admin enforcePriv
- Csnmp-server globalEnforcePriv
- Dsnmp-server user Admin enforceAuth
Correct Answer:
C
Reference:
https://www.cisco.com/c/en/us/td/docs/switches/datacenter/sw/5_x/nx-os/system_management/configuration/guide/sm_nx_os_cg/sm_9snmp.pdf
C
Reference:
https://www.cisco.com/c/en/us/td/docs/switches/datacenter/sw/5_x/nx-os/system_management/configuration/guide/sm_nx_os_cg/sm_9snmp.pdf
send
light_mode
delete
Question #26
Which statement accurately describes MP-BGP EVPN?
- AMP-BGP EVPN is a Layer 3 overlay alternative to VXLANs.
- BThe control plane of the VXLAN overcomes the flood-and-learn limitations of MP-BGP EVPN.
- CThe MP-BGP EVPN control plane overcomes the flood-and-learn limitations of the VXLAN.
- DMP-BGP EVPN is a Layer 2 overlay alternative to VXLANs.
Correct Answer:
B
Reference:
http://www.cisco.com/c/en/us/support/docs/ip/border-gateway-protocol-bgp/200952-Configuration-and-Verification-VXLAN-wit.html
B
Reference:
http://www.cisco.com/c/en/us/support/docs/ip/border-gateway-protocol-bgp/200952-Configuration-and-Verification-VXLAN-wit.html
send
light_mode
delete
Question #27
You plan to implement the OSPF protocol whithin the data center network. Which two statements accurately describe OSPF on the Cisco NX-OS platform?
(Choose two.)
(Choose two.)
- AThe default reference bandwidth is 10 Gbps.
- BOSPF does not require additional licenses.
- CThe OSPF area can be configured by using decimal notation only.
- DRedistributing routes into OSPF requires a route map.
- EThe secondary IP address is advertised by default.
Correct Answer:
CD
Reference:
http://www.cisco.com/c/en/us/td/docs/switches/datacenter/sw/4_2/nx-os/unicast/configuration/guide/l3_cli_nxos/l3_ospf.html#74830
CD
Reference:
http://www.cisco.com/c/en/us/td/docs/switches/datacenter/sw/4_2/nx-os/unicast/configuration/guide/l3_cli_nxos/l3_ospf.html#74830
send
light_mode
delete
Question #28
What can be identified by running the show install all impact kickstart bootflash:n5000-uk9-kickstart.7.0.7.N.1.1.bin system bootflash:n5000-uk9.7.0.7.N1.1a.bin command?
- Awhether the specified kickstart image is compatible with the start-up config
- Bwhether the specified system image supports the kickstart image
- Cwhether bootflash is supported for the specified Cisco NX-OS images
- Dwhether ISSU is supported for the specified Cisco NX-OS images
Correct Answer:
D
D
send
light_mode
delete
Question #29
A Cisco Nexus 2000 Series Fabric Extender is connected to two Cisco Nexus 5000 Series switches via a vPC link. After both Cisco Nexus 5000 Series switches lose power, only one switch is able to power back up. At this time, the Cisco Nexus 2000 Series Fabric Extender is not active and the vPC ports are unavailable to the network.
Which action will get the Cisco Nexus 2000 Series Fabric Extender active when only one Cisco Nexus 5000 Series switch is up and active?
Which action will get the Cisco Nexus 2000 Series Fabric Extender active when only one Cisco Nexus 5000 Series switch is up and active?
- AMove the line from the failed Cisco Nexus 5000 Series switch to the switch that is powered on, so the port channel forms automatically on the switch that is powered on.
- BPower off and on the Cisco Nexus 2000 Series Fabric Extender so that it detected only one Cisco Nexus 5000 Series switch at power up.
- CConfigure auto-recovery reload-delay on the Cisco Nexus 5000 Series switch that is powered on.
- DShut down the peer link on the Cisco Nexus 5000 Series switch that is powered on.
Correct Answer:
C
C
send
light_mode
delete
Question #30
When you configure LISP, which two components must be configured at the site edge? (Choose two.)
- AAED
- BELAN
- CITR
- DEOBC
- EETR
Correct Answer:
CE
Reference:
http://www.cisco.com/c/en/us/td/docs/switches/datacenter/sw/nx-os/lisp/configuration/guide/b_NX-OS_LISP_Configuration_Guide/b_NX-
OS_LISP_Configuration_Guide_chapter_01.html#concept_28F49CFFFDE9400BA76AC944A05BED2D
CE
Reference:
http://www.cisco.com/c/en/us/td/docs/switches/datacenter/sw/nx-os/lisp/configuration/guide/b_NX-OS_LISP_Configuration_Guide/b_NX-
OS_LISP_Configuration_Guide_chapter_01.html#concept_28F49CFFFDE9400BA76AC944A05BED2D
send
light_mode
delete