Netapp NS0-171 Exam Practice Questions (P. 2)
- Full Access (56 questions)
- Six months of Premium Access
- Access to one million comments
- Seamless ChatGPT Integration
- Ability to download PDF files
- Anki Flashcard files for revision
- No Captcha & No AdSense
- Advanced Exam Configuration
Question #6
Which set of commands maps VLAN 100 to VSAN 100?
- ANexus 5000-A#configure terminal Nexus 5000-A (config) # vlan 100 Nexus 5000- A (config-vlan_ #fcoe vsan 100
- BNexus 5000-B# configure terminal Nexus 5000-B (config) # vsan database Nexus 5000-B (config-vsan)# vsan 100 Nexus 5000-B(config- vsan) #vsan 100 name FCoE-VLAN 100
- CNexus 5000-A#configure terminal Nexus 5000-B (config) # vsan database Nexus 5000-A (config)# vsan 100 Nexus 5000-A (config-vsan) # fcoe vsan 100
- DNexus 5000-B# configure terminal Nexus 5000-B(config-vsan) # vlan 100
Correct Answer:
A
?️
Reference -
https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/fcoe/421_n1_1/b_Cisco_n5k_fcoe_config_gd_re_421_n1_1/
Cisco_n5k_fcoe_config_gd_re_421_n1_1_chapter4.html
Reference -
https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/fcoe/421_n1_1/b_Cisco_n5k_fcoe_config_gd_re_421_n1_1/
Cisco_n5k_fcoe_config_gd_re_421_n1_1_chapter4.html
send
light_mode
delete
Question #7
Which feature allows Cisco Nexus 7000 Series switches to be virtualized at the device level?
- APONG
- BVLAN
- CVRF
- DVDC
Correct Answer:
D
?️
Reference -
https://www.cisco.com/c/en/us/products/collateral/switches/nexus-7000-10-slot-switch/White_Paper_Tech_Overview_Virtual_Device_Contexts.html
Reference -
https://www.cisco.com/c/en/us/products/collateral/switches/nexus-7000-10-slot-switch/White_Paper_Tech_Overview_Virtual_Device_Contexts.html
send
light_mode
delete
Question #8
A Cisco UCS chasis has two power suppliers connected to one PDU and two power supplies connected to another PDU. You would like to protect against the failure of one entire PDU.
In this scenario, which power policy should you configure in UCS Manager?
In this scenario, which power policy should you configure in UCS Manager?
- AN+1
- Bredundant
- CN+2
- Dgrid
Correct Answer:
D
?️
Reference -
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/gui/config/guide/3-0/b_UCSM_GUI_User_Guide_3_0/ b_UCSM_GUI_User_Guide_3_0_chapter_0100010.html
Reference -
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/gui/config/guide/3-0/b_UCSM_GUI_User_Guide_3_0/ b_UCSM_GUI_User_Guide_3_0_chapter_0100010.html
send
light_mode
delete
Question #9
Your customer needs a new Nexus switch that can support at least ten 40GbE ports, and has room for future growth. Your customer would also like the new switch to be Application Centric Infrastructure- ready.
Which switch meets these requirements?
Which switch meets these requirements?
- ANexus 7004
- BNexus 5672
- CNexus 6004
- DNexus 9504
Correct Answer:
D
?️
Reference -
https://www.cisco.com/c/en/us/products/collateral/cloud-systems-management/application-policy-infrastructure-controller-apic/datasheet-c78-
732414.html
Reference -
https://www.cisco.com/c/en/us/products/collateral/cloud-systems-management/application-policy-infrastructure-controller-apic/datasheet-c78-
732414.html
send
light_mode
delete
Question #10
After deploying a FlexPod solution, which tool would you use to validate a successful installation?
- AHardware Universe
- BConfig Advisor
- CSystem Manager
- DUCS Manager
Correct Answer:
C
?️
Reference -
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/flexpod_saphana_n9k_aff.html
Reference -
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/flexpod_saphana_n9k_aff.html
send
light_mode
delete
All Pages