Netapp NS0-171 Exam Practice Questions (P. 1)
- Full Access (56 questions)
- Six months of Premium Access
- Access to one million comments
- Seamless ChatGPT Integration
- Ability to download PDF files
- Anki Flashcard files for revision
- No Captcha & No AdSense
- Advanced Exam Configuration
Question #1
What are two valid cluster interconnect switches? (Choose two.)
- ANetApp CN610
- BCisco Nexus 5596
- CCisco Nexus 9504
- DCisco Nexus 7004
send
light_mode
delete
Question #2
A Cisco UCS system is operating in FC End-Host Mode. The fabric Interconnects are uplinked into Nexus 5672UP switches using native FC. The service profiles are unable to boot from SAN using FC. When executing the show flogi database command on the Nexus switches, only the Fabric Interconnect port WWNs are visible. No service profile WWNs are shown.
What caused this issue?
What caused this issue?
- AThe Nexus switches do not have NPV enabled.
- BThe Nexus must be configured for FCoE instead of native Fibre Channel.
- CThe Nexus switches do not have NPIV enabled.
- DThe zoning on the Nexus switches is incorrect.
Correct Answer:
C
?️
Reference -
https://www.cisco.com/c/en/us/products/collateral/servers-unified-computing/ucs-manager/whitepaper_c11-697337.html
Reference -
https://www.cisco.com/c/en/us/products/collateral/servers-unified-computing/ucs-manager/whitepaper_c11-697337.html
send
light_mode
delete
Question #3
Click the Exhibit button.

An administrator is building a FlexPod configuration with UCS 6296 Fabric Interconnect devices that support legacy Fibre Channel 9FC) connections. The administrator uses UCS Manager to configure the unified ports on the Fabric Interconnect.
Referring to the exhibit, how many ports will FC use after the configuration is completed?

An administrator is building a FlexPod configuration with UCS 6296 Fabric Interconnect devices that support legacy Fibre Channel 9FC) connections. The administrator uses UCS Manager to configure the unified ports on the Fabric Interconnect.
Referring to the exhibit, how many ports will FC use after the configuration is completed?
send
light_mode
delete
Question #4
An administrator is configuring a Flexpod Datacenter solution. The UCS service profiles will use FCoE connectivity to the NetApp cluster.
Which pool is needed to configure the vHBA templates?
Which pool is needed to configure the vHBA templates?
send
light_mode
delete
Question #5
Which LIF role is used for SnapMirror traffic on a system running clustered Data ONTAP?
send
light_mode
delete
All Pages