VMware 5V0-62.22 Exam Practice Questions (P. 2)
- Full Access (60 questions)
- Six months of Premium Access
- Access to one million comments
- Seamless ChatGPT Integration
- Ability to download PDF files
- Anki Flashcard files for revision
- No Captcha & No AdSense
- Advanced Exam Configuration
Question #6
A few devices have stopped updating their last seen time within the console. After testing with a device, the administrator notices the Intelligent Hub states AWCM is connected. The administrator decides to review the connection flow to determine the cause of the failure.
Which connection flow should be examined to gain this insight?
Which connection flow should be examined to gain this insight?
- ADevice connection to Device Services
- BDevice Services connection to DB
- CDevice Connection to Console Server
- DAWCM connection to Device Services
Correct Answer:
D
D
send
light_mode
delete
Question #7
An administrator has been troubleshooting an issue where a single device is unable to check in to VMware Workspace ONE UEM and receive commands. All services are functioning, and this issue appears to be isolated to this specific device. Service logs have also been reviewed and do not show any instances of communication with the device in question.
Which troubleshooting step should be taken next to find the root cause, while not causing any data loss to the end user's device?
Which troubleshooting step should be taken next to find the root cause, while not causing any data loss to the end user's device?
- AGather Device Side Logging.
- BRenew the Device Root Certificate.
- CManually update the device record in the DB.
- DUse Device Wipe, and then re-enroll the device.
Correct Answer:
A
A
send
light_mode
delete
Question #8
An administrator has assigned a purchased application to a new group of DEP devices and enabled device-based-licensing. However, none of the assigned devices could install the application.
Which statement describes the possible cause of this problem?
Which statement describes the possible cause of this problem?
- ADevices do not have Workspace ONE Hub installed.
- BVPP invites are not accepted.
- CVPP sToken has expired.
- DApp Store is hidden.
Correct Answer:
B
B
send
light_mode
delete
Question #9
An organization administrator configures VMware Workspace ONE UEM to deploy a new internal Win32 application to Windows devices, which are all located in the same OG (organization group). Users of newer Windows devices with increased hardware capacities can install this application, but older Windows devices with lower capacities are unable to complete the installation.
What is the most likely cause of this issue?
What is the most likely cause of this issue?
- AThe organization’s Windows Azure AD credentials in their Microsoft Store for Business expired.
- BThe VMware Workspace ONE administrator set “RAM Required” for the application in the "Details" tab options.
- CThe assignment of the internal application via the common OG (organization group) is misconfigured.
- DThe VMware Workspace ONE administrator set “Admin Privileges” for the application in the "Details" tab options.
Correct Answer:
B
B
send
light_mode
delete
Question #10
Where should the logging level for AirWatch Cloud Connector be changed?
- AIn the CloudConnectorHub.exe.config file
- BAt the Workspace ONE Access Connector settings page
- CIn the CloudConnector.exe.config file
- DAt the UEM console Cloud Connector settings page
Correct Answer:
C
C
send
light_mode
delete
All Pages