Question #16
A 30-minute power maintenance window has been approved on Sunday. Due to a delay, the maintenance took 20 minutes longer to finish.
During this time, the vSAN administrator noticed that one of the clusters nodes was affected by a power shortage, as it was connected to an affected power source. The default vSAN storage policy has been applied.
What will be the status of the vSAN objects on the affected host immediately after it is recovered?
During this time, the vSAN administrator noticed that one of the clusters nodes was affected by a power shortage, as it was connected to an affected power source. The default vSAN storage policy has been applied.
What will be the status of the vSAN objects on the affected host immediately after it is recovered?
- AThe cluster will be partitioned and the vSAN host will need to be rejoined.
- BA rebuild of the affected objects will occur.
- CAll objects will remain accessible.Most Voted
- DAll objects on the affected host will be lost.
Correct Answer:
B
B
send
light_mode
delete
Question #17
Due to the success of the recently deployed developer-only private cloud solution, a company has a new requirement to at least double the usable capacity in their all-flash vSAN cluster.
The vSAN cluster is deployed into a co-located datacenter that is owned by a third-party hosting company. The hosting company charges a fixed monthly cost for rack space and power consumption. The service owner has been given a limited budget for additional hardware purchases, but not for on-going co-location costs.
The current vSAN cluster has the following configuration:
✑ 10 vSAN Nodes with 2 CPUs (20 cores), 512 GB RAM
✑ 1 Disk Group per vSAN node
- 1 x 400 GB
- 4 x 1.8 TB
✑ De-duplication and Compression is enabled.
✑ vSAN Capacity is currently:
- Total: 72 TB
- Usable: ~40 TB (FTT1/RAID1) and ~60 TB (FTT1/RAID5).
As a result of any action taken, the service owner would like to ensure that overall availability of the vSAN cluster is increased.
Which two recommendations meet the requirement to increase capacity while maintaining service availability? (Choose two.)
The vSAN cluster is deployed into a co-located datacenter that is owned by a third-party hosting company. The hosting company charges a fixed monthly cost for rack space and power consumption. The service owner has been given a limited budget for additional hardware purchases, but not for on-going co-location costs.
The current vSAN cluster has the following configuration:
✑ 10 vSAN Nodes with 2 CPUs (20 cores), 512 GB RAM
✑ 1 Disk Group per vSAN node
- 1 x 400 GB
- 4 x 1.8 TB
✑ De-duplication and Compression is enabled.
✑ vSAN Capacity is currently:
- Total: 72 TB
- Usable: ~40 TB (FTT1/RAID1) and ~60 TB (FTT1/RAID5).
As a result of any action taken, the service owner would like to ensure that overall availability of the vSAN cluster is increased.
Which two recommendations meet the requirement to increase capacity while maintaining service availability? (Choose two.)
- AInstall an additional 400 GB SSD and 4 x 1.8 TB SSDs per vSAN node.Most Voted
- BUpdate the existing Disk Group, and claim the newly installed drives for each node.
- CCreate a new Disk Group, and claim the newly installed cache and capacity SSD drives for each node.Most Voted
- DInstall an additional 3 x 1.8 TB SSDs per vSAN node.
- EReplace existing SSDs with an 800 GB SSD and 4 x 3.8 TB SSDs per vSAN node.
Correct Answer:
CD
CD
send
light_mode
delete
Question #18
After a vSAN Witness Appliance network configuration, the vSAN administrator notices that vSAN traffic flows from vmk0 (Management Traffic) rather than vmk1
(vSAN Traffic).
Which step should be taken to resolve this issue?
(vSAN Traffic).
Which step should be taken to resolve this issue?
- AConfigure vmk0 with IP address on the same range as that of vmk1.
- BTag the vmk0 for vSAN traffic.
- CConfigure vmk1 with IP address on the different network than that of vmk0.Most Voted
- DTag the vmk1 for Witness traffic.
Correct Answer:
A
Explanation -
If both vmk0 and vmk1 are configured on the same range, a multihoming condition will occur and vSAN traffic will flow from vmk0, rather than vmk1.
Reference:
http://www.vmwarearena.com/vsan-stretched-cluster-how-to-configure-vsan-witness-appliance/
A
Explanation -
If both vmk0 and vmk1 are configured on the same range, a multihoming condition will occur and vSAN traffic will flow from vmk0, rather than vmk1.
Reference:
http://www.vmwarearena.com/vsan-stretched-cluster-how-to-configure-vsan-witness-appliance/
send
light_mode
delete
Question #19
A customer has upgraded to vSAN 7, but there is still an existing legacy host which must be removed from the vSAN cluster.
Which three steps must an administrator take to successfully remove this host from the vSAN cluster? (Choose three.)
Which three steps must an administrator take to successfully remove this host from the vSAN cluster? (Choose three.)
- APlace the host in maintenance mode with Ensure Accessibility
- BDisconnect from vCenter Server
- CPlace the host in maintenance mode with Full Data migrationMost Voted
- DPlace the host in maintenance mode with no data migration
- ERemove from vSAN clusterMost Voted
- FDelete the disk group(s) on the legacy hostMost Voted
Correct Answer:
CEF
Reference:
http://www.vexpertconsultancy.com/2019/06/step-by-step-remove-a-node-permanently-from-a-vsan-cluster/
CEF
Reference:
http://www.vexpertconsultancy.com/2019/06/step-by-step-remove-a-node-permanently-from-a-vsan-cluster/
send
light_mode
delete
Question #20
During a vSAN design workshop, an architect collected these customer requirements:
✑ Leverage vSAN storage policies with Erasure Coding.
✑ Enable Deduplication and Compression.
✑ Use the minimum number of hosts in the cluster.
✑ Maintain full storage policy compliance when two nodes are down.
Which vSAN cluster design meets the customer's requirements?
✑ Leverage vSAN storage policies with Erasure Coding.
✑ Enable Deduplication and Compression.
✑ Use the minimum number of hosts in the cluster.
✑ Maintain full storage policy compliance when two nodes are down.
Which vSAN cluster design meets the customer's requirements?
- AFive nodes All-Flash vSAN cluster
- BSix nodes All-Flash vSAN clusterMost Voted
- CSix nodes Hybrid vSAN cluster
- DFive nodes Hybrid vSAN cluster
Correct Answer:
B
Reference:
https://www.vmware.com/files/pdf/products/vsan/vmware-vsan-62-space-efficiency-technologies.pdf
B
Reference:
https://www.vmware.com/files/pdf/products/vsan/vmware-vsan-62-space-efficiency-technologies.pdf