VMware 2VB-601 Exam Practice Questions (P. 5)
- Full Access (60 questions)
- Six months of Premium Access
- Access to one million comments
- Seamless ChatGPT Integration
- Ability to download PDF files
- Anki Flashcard files for revision
- No Captcha & No AdSense
- Advanced Exam Configuration
Question #21
What is required when enabling deduplication and compression in a vSAN cluster?
- AHost client cache enabled
- BAt least two disk groups in every host
- CAn all-flash configuration
- DMore than three hosts
Correct Answer:
C
References:
https://docs.vmware.com/en/VMware-vSphere/6.5/com.vmware.vsphere.virtualsan.doc/GUID-2285B446-46BF-429C-A1E7-BEE276ED40F7.html
C
References:
https://docs.vmware.com/en/VMware-vSphere/6.5/com.vmware.vsphere.virtualsan.doc/GUID-2285B446-46BF-429C-A1E7-BEE276ED40F7.html
send
light_mode
delete
Question #22
A 12-node vSAN cluster has been deployed across three server racks in a data center.
✑ There are four nodes in each server rack.
✑ A vSAN fault domain has been configured for each server rack for a total of three fault domains.
✑ All virtual machines in the cluster have the vSAN default storage policy assigned to them.
✑ This policy has not been modified.
✑ vSphere HA is enabled for the cluster.
✑ One of the server racks loses power.
How does this affect virtual machines running on this cluster?
✑ There are four nodes in each server rack.
✑ A vSAN fault domain has been configured for each server rack for a total of three fault domains.
✑ All virtual machines in the cluster have the vSAN default storage policy assigned to them.
✑ This policy has not been modified.
✑ vSphere HA is enabled for the cluster.
✑ One of the server racks loses power.
How does this affect virtual machines running on this cluster?
- ASince there are four nodes in each server rack, erasure coding is used to rebuild data that was lost due to the server rack power failure. vSphere HA monitors the rebuild process and powers on all affected virtual machines after the rebuild process is complete.
- BVirtual machine data in the failed server rack is rebuilt immediately using parity information. vSphere HA powers off and restarts all of the virtual machines to rebalance storage utilization across the cluster.
- CAll virtual machine data remains accessible. Virtual machines running on nodes in the failed server rack are restarted on nodes in the other two server racks. Virtual machines in the other two server racks continue to run.
- DVirtual machines running on nodes in the failed server rack remain offline for 60 minutes. Virtual machines in the other two server racks continue to run and are
Correct Answer:
C
C
send
light_mode
delete
Question #23
Which of the listed configurations is a supported vSAN configuration?
- AFour physical hosts Every host has one vSAN disk group Each vSAN disk group contains one cache device and five capacity devices The vSAN service is enabled on a VMkernel adapter on every host
- BThree physical hosts Every host has one vSAN disk group Each vSAN disk group contains two cache devices and four capacity devices The vSAN service is enabled on a VMkernel adapter on every host
- CFour physical hosts Two of the host have one vSAN disk group, the other two hosts are "compute-only" nodes Each vSAN disk group contains one cache device and three capacity devices The vSAN service is NOT enabled on the "compute-only" nodes
- DFour physical hosts Two of the host have one vSAN disk group, the other two hosts are "compute-only" nodes Each vSAN disk group contains one cache device and three capacity devices
Correct Answer:
A
A
send
light_mode
delete
Question #24
Which replication solution is supported with vSAN and Site Recovery Manager?
- AvSAN iSCSI synchronous replication
- BvSphere Replication
- CvSAN iSCSI asynchronous replication
- DvSphere Fault Tolerance
Correct Answer:
B
References:
https://docs.vmware.com/en/VMware-Site-Recovery/services/com.vmware.srmaas.admin.doc/GUID-5937A071-B1AA-4224-B508-4D244D252C52.html
B
References:
https://docs.vmware.com/en/VMware-Site-Recovery/services/com.vmware.srmaas.admin.doc/GUID-5937A071-B1AA-4224-B508-4D244D252C52.html
send
light_mode
delete
Question #25
View the exhibit.
The exhibit shows a single node of a vSAN cluster. All nodes have been configured identically.
Which statement is true about the exhibit?

The exhibit shows a single node of a vSAN cluster. All nodes have been configured identically.
Which statement is true about the exhibit?

- AThis is an invalid design. There are too many disk groups.
- BThis is an invalid design. You CANNOT mix all-flash disk groups with hybrid disk groups.Most Voted
- CThis is a valid all-flash vSAN configuration.
- DThis is a valid hybrid vSAN configuration.
- EThis is an invalid design. There are too few capacity disks.
Correct Answer:
A
A
send
light_mode
delete
All Pages