Question #16
An LTM Specialist has installed a hotfix that updated the SCCP firmware package.
Which command will ensure that the host subsystem and SCCP reboot?
Which command will ensure that the host subsystem and SCCP reboot?
- Areboot
- Bfull_box_reboot
- Cshutdown -r now
- DThe reboot should be initiated via the HTTPS administration GUI.
Correct Answer:
B
B
send
light_mode
delete
Question #17
Which procedure should an LTM Specialist follow to move a configuration from a 1500 to a 1600 hardware platform during an upgrade?
- Atmsh save sys config file filename.scf copy the file from the /var/local/scf directory from one device to the other tmsh load sys config file filename.scf
- Btmsh save sys backup file filename.scf copy the file from the /var/local/scf directory from one device to the other tmsh load sys backup file filename.scf
- Ctmsh save sys backup file filename.scf copy the file from the /var/local/ucs directory from one device to the other tmsh load sys backup file filename.scf
- Dtmsh save sys config file filename.scf copy the file from the /var/local/ucs directory from one device to the other
Correct Answer:
A
A
send
light_mode
delete
Question #18
What is the recommended procedure for upgrading a major TMOS release on a BIG-IP platform?
- A1. Renew the device license. 2.Take a configuration backup. 3.Reboot the device to the non-active volume. 4.Upload the device code. 5.Install device code to the current volume.
- B1. Take a configuration backup. 2.Upload the device code. 3.Install device code to the non-active volume. 4.Reboot the device to the non-active volume. 5.Renew the device license.
- C1. Renew the device license. 2.Take a configuration backup. 3.Upload the device code. 4.Install device code to the non-active volume. 5.Reboot the device to the non-active volume.
- D1. Take a configuration backup. 2.Reboot the device to the non-active volume. 3.Renew the device license. 4.Upload the device code.
Correct Answer:
C
C
send
light_mode
delete
Question #19
An LTM Specialist uploaded new releases .iso and .md5 files titled "BIGIP-FILENAME" via the GUI.
Which commands are run via the command line from the root directory to verify the integrity of the new .iso file?
Which commands are run via the command line from the root directory to verify the integrity of the new .iso file?
- Acd /var/shared/images md5sum --check BIGIP-FILENAME.iso
- Bcd /shared/images md5sum --check BIGIP-FILENAME.iso
- Ccd /var/shared/images md5sum --check BIGIP-FILENAME.iso.md5
- Dcd /shared/images
Correct Answer:
D
D
send
light_mode
delete
Question #20
An LTM Specialist must perform a hot fix installation from the command line.
What is the correct procedure to ensure that the installation is successful?
What is the correct procedure to ensure that the installation is successful?
- Aimport the hot fix to the /var/shared/images directory check the integrity of the file with an md5 checksum tmsh apply sys software hotfix volume <volume_name> <hotfix_name>.iso
- Bimport the hot fix to the /var/shared/images directory check the integrity of the file with an md5 checksum tmsh install sys software hotfix <hotfix_name>.iso volume <volume_name>