Dell E22-285 Exam Practice Questions (P. 2)
- Full Access (80 questions)
- Six months of Premium Access
- Access to one million comments
- Seamless ChatGPT Integration
- Ability to download PDF files
- Anki Flashcard files for revision
- No Captcha & No AdSense
- Advanced Exam Configuration
Question #6
When adding a VxRail node the validation fails. What could be the cause of this problem?
- AIPv6 multicasting is not enabled
- BOnly one network interface online
- CTime on the node was not set correctly
- DDNS record was not created
Correct Answer:
B
Reference -
https://community.emc.com/thread/236186?start=0&tstart=0
B
Reference -
https://community.emc.com/thread/236186?start=0&tstart=0
send
light_mode
delete
Question #7
You are asked to cable up a VxRail G Series cluster to a redundant pair of 1/10G switches. What is the cabling best practice for this configuration?
- ACable ports 1 and 2 to one switch. Cable ports 3 and 4 to the other switch.
- BCable ports 1 and 2 to one switch. Cable ports 3 and 4 to the other switch. Cable BMC from node 1 and 2 to one switch. Cable BMC from node 3 and 4 to the other switch.
- CCable ports 1 and 3 to one switch. Cable ports 2 and 4 to the other switch.
- DCable ports 1 and 3 to one switch. Cable ports 2 and 4 to the other switch. Cable BMC from node 1 and 3 to one switch. Cable BMC from node 2 and 4 to the
Correct Answer:
D
D
send
light_mode
delete
Question #8
A company is in the process of configuring their Top of Rack (ToR) switches as a single rack that replicates to a secondary data center with vSphere Replication.
What is a consideration for this configuration?
What is a consideration for this configuration?
- AIPv6 and IPv4 multi-cast should be layer-3 routed between data centers
- BIPv6 and IPv4 multi-cast should span the entire network in each data center
- CIPv6 and IPv4 multi-cast traffic does not need to leave the ToR switches
- DIPv6 and IPv4 multi-cast traffic should span layer-2 between data centers
Correct Answer:
B
B
send
light_mode
delete
Question #9
In a VxRail external vCenter deployment, which component(s) are automatically licensed?
- AvCenter only
- BvCenter and vSAN
- CNone
- DvSAN only
Correct Answer:
B
Reference -
https://www.emc.com/collateral/guide/h15844-vxrail-4-0-vcenter-server-pg.pdf
(page 5)
B
Reference -
https://www.emc.com/collateral/guide/h15844-vxrail-4-0-vcenter-server-pg.pdf
(page 5)
send
light_mode
delete
Question #10
When using vSphere Web Client, what is the source of information that can help validate good VxRail system post-deployment status?
- AMARVIN-Virtual-SAN-Cluster > Monitor > Health Logical View
- BMARVIN-Virtual-SAN-Cluster > Monitor > Virtual SAN > Health
- CLast Heartbeat, Last Configuration Sent, Network Environment Settings, Cluster Monitor
- DSystem Diagnostic, Events, Health Logical View, Health Physical View, Log Bundle
Correct Answer:
D
D
send
light_mode
delete
All Pages