Question #1
A customer wants to deploy NVMe/FC along with an existing FC SAN fabric using ONTAP 9.8.
In this scenario, which two actions are correct? (Choose two.)
In this scenario, which two actions are correct? (Choose two.)
- AEnable NVMe/FC on the existing FC SVM.
- BCreate new zoning on fabric switches.
- CUpgrade your FC switches from 16 GB to 32 GB.
- DUse existing zoning on fabric switches.
send
light_mode
delete
Question #2
Click the Exhibit button.

You are configuring a new NetApp ONTAP cluster and are connecting the nodes to Cisco MDS SAN switches. You connect one of the nodes to switch port fc1/11 and run the commands that are shown in the exhibit. The SAN LIFs are enabled but are not operationally online, and none of the SAN hosts can access their LUNs on the ONTAP cluster.
In this scenario, which configuration would cause this problem?

You are configuring a new NetApp ONTAP cluster and are connecting the nodes to Cisco MDS SAN switches. You connect one of the nodes to switch port fc1/11 and run the commands that are shown in the exhibit. The SAN LIFs are enabled but are not operationally online, and none of the SAN hosts can access their LUNs on the ONTAP cluster.
In this scenario, which configuration would cause this problem?
- ANPIV is not enabled on the switches.
- BInteroperability mode is not enabled on the switches.
- CNPV is not enabled on the switches.
- DThe in-order guarantee is not enabled on the switch.
send
light_mode
delete
Question #3
You are installing an AFF A250 system with ONTAP 9.8 software. Your customer asks you about the recommended LIF configuration for the iSCSI protocol.
In this scenario, which two statements are correct? (Choose two.)
In this scenario, which two statements are correct? (Choose two.)
- AEach node in an iSCSI configuration must be connected to a minimum of two Ethernet switches.
- BEach SVM in an iSCSI configuration must have a minimum of two LIFs per node.
- CAll LIFs from the SVM are connected to a single Ethernet switch.
- DEach SVM in an iSCSI configuration must have a minimum of one LIF per node.
send
light_mode
delete
Question #4
A customer has a 4-node cluster consisting of a FAS8020 system and an AFF A220 system that is running iSCSI workloads across two separate SVMs. The FAS8020 system is reaching end of support, so they add a new AFF A400 system to migrate workloads off the FAS8020 system. The customer wants to migrate data off the FAS8020 aggregate n1_aggr1 on SVM2 to the AFF A400 aggregate n5_aggr1 on SVM1.
In this scenario, which NetApp command would accomplish this task?
In this scenario, which NetApp command would accomplish this task?
- Avolume move
- Baggregate reallocation
- Cvolume reallocation
- Dvolume rehost
send
light_mode
delete
Question #5
Which NetApp tool provides a detailed inventory of SAN components?
- AHardware Universe
- BActive IQ Config Advisor
- CInteroperability Matrix Tool
- DActive IQ OneCollect
send